Differential pressure
Search results: 49-58 of 58
Dwyer ATEX differential pressure controller series AT2DH3
Dwyer ATEX approved differential pessure switch series AT1ADPS
Dual differential pressure transmitter for air handling series KPEL
The KPEL series combines two differential pressure measurements in a single transmitter. These dual differential pressure transmitters can be used to monitor two filters with one device. The measuring range can be selected in the field from 100 Pa to 2500 Pa. Optional versions are available with a display and/or Modbus communication.
Differential pressure transmitter for water series VPEL
The VPEL series differential pressure transmitters are developed for measuring water (glycol) pressure differences in cooling systems and central heating installations. The VPEL series is optionally available with a display.
Differential pressure transmitter for air handling series PEL8K
The Produal PEL8K series consists of straightforward differential pressure transmitters for measuring static pressure and fan pressure in air ducts. In the field, the measuring range can be set from 1000 to 8000 Pa. Optional versions are available with a display and/or Modbus communication.
Differential pressure transmitter for air handling series PEL
The PEL series differential pressure transmitters offer high reliability. They are suitable for building automation applications where extra accuracy and stability are required. Using jumpers, the measuring range can easily be adjusted in the field. In addition to filter monitoring and belt break detection, the PEL series is also highly suitable for measuring very low differential pressures, s…
Differential pressure transmitter for air handling and filter monitoring series PEL2500
The Produal PEL2500 series consists of straightforward differential pressure transmitters for filter monitoring and measuring static pressures in air ducts. In the field, the measuring range can be set to 100, 200, 500, 1000, 1500, 2000, or 2500 Pa. Optional versions are available with a display and/or Modbus communication.
Differential pressure transmitter for air handling and filter monitoring series PEL1000
The Produal PEL1000 series consists of straightforward differential pressure transmitters for filter monitoring and measuring static pressures in air ducts. In the field, the measuring range can be set to 500 or 1000 Pa. Optional versions are available with a display and/or Modbus communication.
Differential pressure transmitter for DIN rail mounting series 616KD
The Dwyer 616KD differential pressure transmitters are compact and designed for DIN rail mounting. The 616KD series is available in various accuracies, up to 0.25%, and in a range of measurement spans. With simple calibration buttons, you can easily set the zero and span points, saving time during installation and maintenance.